Portable Logging Turbidity Meter浊度计93703

商品名称:  Portable Logging Turbidity Meter浊度计93703

商品编号:  HI93703-11

商品规格:  Portable Logging Turbidity Meter

净重含量:  便携式浊度计

  • GLP Features
  • 3 point calibration
  • Logging for up to 199 measurements (AHI 93703-11)
  • PC Connectivity (AHI 93703-11)

 

AHI 93703 series are microprocessor based turbidity meters that provide laboratory accuracy for field turbidity measurements.

The AHI 93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.

HANNA instruments has chosen 10 FTU* as the calibration point because it is the value that best fits the water turbidity measurements in different applications, from drinking water to wastewater treatment. HANNA instruments uses the primary standard AMCO-AEPA-1 to avoid all formazine-related problems. Formazine is a very toxic, unstable substance which requires particular care: its standards have to be prepared only a few minutes before performing the calibration, and cannot be reused because of their short life. HANNA AMCO-AEPA-1 standards are extremely stable, can be reused, and last up to six months if free from contamination.A HI 93703 can be used with both standards.

The AHI 93703-11 enhanced version features a real-time clock, logging for up to 199 measurements and PC compatibility via the RS232 interface and Windows® compatible AHI 92000 software.

Both versions meet the requirements of GLP (Good Laboratory Practice) protocols for last calibration data storage.

 

Order Information:
AHI 93703 is supplied complete with glass cuvette, batteries and instructions.
AHI 93703-11 is supplied complete with glass cuvette, batteries and instructions.
AHI 93703C, kit including AHI 93703 andA HI 731313 maintenance kit.

Range   0.00 to 50.00 FTU;
50 to 1000 FTU
Resolution   0.01 FTU (0.00 to 50.00 FTU);
1 FTU (50 to 1000 FTU)
Accuracy   ±0.5 FTU or ±5% of reading (whichever is greater)
Calibration   3 points (0 FTU, 10 FTU and 500 FTU)
Light Source   infrared LED
Light Detection   Silicon Photocell
Battery Type / Life   1.5V AA (4) /approximately 60 hours of continuous use or 900 measurements; auto-off after 5 minutes of non-use
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   220 x 82 x 66 mm (8.7 x 3.2 x 2.6")
Weight   510 g (1.1 lb.)

Range   0.00 to 50.00 FTU;
50 to 1000 FTU
Resolution   0.01 FTU (0.00 to 50.00 FTU);
1 FTU (50 to 1000 FTU)
Accuracy   ±0.5 FTU or ±5% of reading (whichever is greater)
Calibration   3 points (0 FTU, 10 FTU and 500 FTU)
Light Source   infrared LED
Light Detection   Silicon Photocell
Battery Type / Life   1.5V AA (4) /approximately 60 hours of continuous use or 900 measurements; auto-off after 5 minutes of non-use
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   220 x 82 x 66 mm (8.7 x 3.2 x 2.6")
Weight   510 g (1.1 lb.)